General Info

Guard Net is complete single door network controller for two locks and it works with two readers. It has two RS-485 network ports for further independent connection to USB or IP converter. First lock is used at daytime. This lock has very large number of possible working cycles and fast response time. Second lock is more rigid and used at night time to have higher security level.

These locks can be managed by:

1) Several types of proximity cards with additional PIN codes

2) Fire and Alarm inputs

3) Special time schedules

4) Remote commands from PC

Specifications/ Working modes

Controller can be in one of six static working modes. Modes are shown with LED indication on reader.

1) Day Time mode. Day lock is closed and can be opened with appropriate card. Night Lock is opened. Red LED is on.

2) Night Time mode. Both locks are closed. When this mode is activated in current controller information is send over to other controllers connected under Guard Light software or in same RS-485 line under Z-397 IP converter (if allowed by setting configured over USB). Red LED is blinking.

3) Free mode. Both locks are opened. Green LED is on.

4) Fire mode. Both locks are opened. When this mode is activated in current controller information is send over to other controllers connected under Guard Light software or in same RS-485 line under Z-397 IP converter (if allowed by setting configured over USB).Warning sound and red LED blinking are on.

5) Waiting mode. Can be turned on remotely from PC or by schedule for further changing to Free mode at moment when first valid Normal card is applied to reader. Green LED is blinking.

6) Warning. Turned on if there is no confirmation from Night Lock about successful closing.